|
Tips
Home - Fire sprinkler
Fire sprinklers
are an active fire protection measure subject to stringent bounding. They
are connected to a fire suppression system that consists of overhead pipes
fitted with sprinkler heads throughout the coverage area. Fire sprinkler
systems for high-rises are usually also equipped with a fire pump, and
a jockey pump and are tied into the fire alarm system. Although historically
only used in factories and large commercial buildings, home and small
building systems are now available at a relatively cost-effective price.
From 1852 to 1885,
perforated pipe systems were used in textile mills throughout New England
as a means of fire protection. However, they were not automatic systems;
they did not turn on by themselves. Inventors first began experimenting
with automatic sprinklers around 1860. The first automatic sprinkler system
was patented by Philip W. Pratt of Abington, MA, in 1872.
Henry S. Parmalee
of New Haven, Connecticut is considered the inventor of the first practical
automatic sprinkler head. Parmalee improved upon the Pratt patent and
created a better sprinkler system. In 1874, he installed his fire sprinkler
system into the piano factory that he owned.
Until the 1940s, sprinklers
were installed almost exclusively for the protection of commercial buildings,
whose owners were generally able to recoup their expenses with savings
in insurance costs. Over the years, fire sprinklers have become mandatory
safety equipment, and are required by building codes to be placed in hospitals,
schools, hotels and other public buildings.
Sprinklers have been
in use in the United States since 1874, and were used in factory applications
where fires at the turn of the century were often catastrophic in terms
of both human and property losses. In the US, sprinklers are today required
in all new high rise and underground buildings generally 75 feet (23 m)
above or below fire department access, where the ability of firefighters
to provide adequate hose streams to fires is limited. Sprinklers may also
be required in hazardous storage spaces by building codes, or may be required
by insurance companies where liability due to potential property losses
or business interruptions can be reduced by adequate automatic fire protection.
Building codes in the United States for places of assembly, generally
over 100 persons, and places with overnight sleeping accommodation such
as hotels, nursing homes, dormitories, and hospitals usually require sprinklers.
A newer, special class of fire sprinklers, ESFR sprinklers, has been developed
to fight, and subsequently suppress high challenge type fires.
Each sprinkler head
is held closed independently by heat-sensitive seals. These seals prevent
water flow until a design temperature is exceeded at the individual sprinkler
heads.
Each sprinkler activates
independently when the predetermined heat level is reached. The design
intention is to limit the total number of sprinklers that operate, thereby
providing the maximum water supply available from the water source to
the point of fire origin.
Typical "wet"
systems are simple and passive. They have water already pressurized in
the pipes held back by the sprinkler head. These systems require no manual
controls to activate, so long as adequate water supplies are provided.
Specialty systems
called "dry" systems, designed for unheated spaces, have a low
"maintenance" air pressure in the pipes. Water is fed into the
system when the sprinkler "fuses" allowing the maintenance air
pressure to reach the minimum pressure point. "Pre-action" systems
are highly specialized for locations where accidental activation is unacceptable
such as museums with rare art works, manuscripts, or books. Pre-action
valves are connected to fire alarm initiating devices such as smoke detectors
or heat detectors and virtually eliminate the possibility of accidental
water flow.
"Deluge"
systems are "pre-action" systems that have open sprinklers,
i.e. the fusible link is removed, so that every sprinkler served by the
system will discharge water. This ensures a large and simultaneous application
of water over the entire hazard. These systems are used for special hazards
where rapid fire spread is a concern.
Other specialty systems
may have foam instead of water suppression agents for fire protection
in occupancies with flammable liquids, such as airport hangars. "Clean
agent" gaseous systems, such as Argon/CO2/Nitrogen mixtures can be
used in very small spaces where water cannot be used for suppression.
A sprinkler activation
will do less damage than a fire department hose, as the fire department's
hose streams provide around 250 US gallons per minute (15 L/s) whereas
an activated sprinkler head generally discharges around 23 US gallons
per minute (1.5 L/s).
In 2006, cost of sprinkler
systems run from US$2 - $5 per square foot ($50/m²), depending on
type and location, however specialty systems may cost as much as $10/square
foot ($100/m²). Systems can be installed during construction or retrofitted.
Some communities have laws requiring residential sprinkler systems, where
large municipal hydrant water supplies ("fire flows") are not
available. Nationwide in the United States, one and two-family homes generally
do not require fire sprinkler systems, although the overwhelming loss
of life due to fires occurs in these spaces. Residential sprinkler systems
are relatively inexpensive (about the same per square foot as carpeting
or floor tiling), but require larger water supply piping than is normally
installed in homes, so retrofitting is usually cost prohibitive.
According to the National
Fire Protection Association (NFPA), fires in hotels with sprinklers averaged
78% less damage than fires in hotels without them (1983-1987). The NFPA
says the average loss per fire in buildings with sprinklers was $2,300,
compared to an average loss of $10,300 in unsprinklered buildings. The
NFPA adds that there is no record of a fatality in a fully sprinklered
building outside the point of fire origin. However, in a purely economic
comparison, this is not a complete picture; the total costs of fitting,
and the costs arising from non-fire triggered release must be factored.
|